Elemco International Limited

Home     Mail     Contact us

 

  ELEMCO INVESTMENT NIGERIA LIMITED

ABOUT US
OUR VISION
SERVICES
PRODUCTS
ASSOCIATES
PROJECT MANAGEMENT
HEALTH & SAFETY
GLOBAL PROCUREMENT

 

 

 
         

    Systems Solution

    Safety Barriers
    Isolators
    Remote I/O - I.S.  1
    Fieldbus ISbus
     Operating and monitoring Systs
    Lightings
    Installation Equipment
    Control Stations and Control
    Devices
    Signaling Devices
    Components for heating systs.
    Load disconnect switches and
    Motor starters.
    Applications Low Voltage Syst.
    Components for systems
    solution
    Installation Equipment and
    Accessories
    NEC and CEC-Products
 
 

 

         

Emergency Light Fittings

 
 

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

 
Compact Emergency Light Fittings Series C-LUX 6108 / 6508
  • Operating modes
    • non-maintained operation
    • non-maintained operation with switchable emergency light blocking
  • With continous operating test
  • For fluorescent lamps 8 W,  16 mm, for two-pin holder G5
  • Suitable for wall and ceiling mounting
  • Can be fitted to order with emergency exit signs
  • Central locking
  ATEX
Zone 0 1 2 20 21 22
6108: For use in   x x   x x
6508: For use in     x   x x
 
 

Compact Sheet-steel Emergency Light Fitting Series 6118

 
Compact Sheet-steel Emergency Light Fitting Series 6118
  • Electronic ballast with integrated emergency light unit for continuous operation
  • Tests
    • With weekly functional test
    • With automatic emergency light duration test
  • With discharge protection and charging voltage limitation
  • For fluorescent lamps 8 W
  • Central locking
  • Enclosure in powder-coated sheet steel or stainless steel
  ATEX
Zone 0 1 2 20 21 22
For use in   x x      
 
 

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

 
Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
  • As pendant light fitting or side entry lamp
  • Version with 2 lamps: 18 W and 36 W
  • Central locking
  • Weekly functional test
  • Light duration test of the emergency lighting every six months
  ATEX / IECEx     Class I (NEC 505) (NEC 506)     Class I Class II Class III
Zone 0 1 2 20 21 22   Zone 0 1 2 20 21 22   Division 1 2 1 2 1 2
EXLUX 6008:
For use in
  x     x x   EXLUX 6008:
For use in
  x x         EXLUX 6008:
For use in
  x x x x x
EXLUX 6408:
For use in
    x*)   x*) x*)   EXLUX 6408:
For use in
    x         EXLUX 6408:
For use in
  x x x x x
 
 

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

 
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
  • For fluorescent lamps 2 x 18 W and 2 x 36 W
  • For emergency light operation periods of 1.5 or 3 hrs
  • During emergency time: If emergency lamp broken changing to the other lamp
  • Battery case which can be opened separately for easy change of batteries by means of plug-type contacts
  • Enclosure closed by means of quick-action locks
  ATEX     Class I (NEC 505) (NEC 506)     Class I Class II Class III
Zone 0 1 2 20 21 22   Zone 0 1 2 20 21 22   Division 1 2 1 2 1 2
For use in     x   x x   For use in     x         For use in   x x x x x
 
 

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 Economy

 
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 Economy
  • For use in
    • Zone 2
    • Zonen 21 & 22
  • For fluorescent lamps 2 x 18 W and 2 x 36 W
  • With electronic ballast and integrated emergency lighting electronics
  • For emergency light operation periods of 1.5 hrs
  • Intelligent charging method
  • Housing made of glass-fibre reinforced polyester resin, diffuser cover made of shockresistant polycarbonate
  • Housing sealed with quick-action fasteners
Zones 2, 21 & 22
 
 
 

Sheet Steel Emergency Light Fitting Series 6018

 
Sheet Steel Emergency Light Fitting Series 6018
  • For an operating duration of 1.5 or 3 h
  • Operating modes
    • Continuous operation
    • Continuous operation with switchable emergency light blocking
  • Weekly functional test
  • Total discharge protection and charging voltage limitation
  • Enclosure in powder-coated steel sheet or stainless steel
  ATEX
Zone 0 1 2 20 21 22
For use in   x x      

 

     