Digital Output Module 4-Channel Version Series 9475/.2-04-.. from Rev. F

 
Digital Output Module 4-Channel Version Series 9475/.2-04-.. from Rev. F
  • 4 channels for Ex i / I.S. solenoid valves, piezo and booster valves
  • Intrinsically safe outputs Ex ia IIC
  • Additional input for "Plant-STOP" available (acc. to IEC 61508 up to SIL 2)
  • Galvanic isolation between outputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Functions with adjustable parameters
  • Module can be replaced in operation (hot swap)

 

Zone

0

1

2

20

21

22

Class

I

II / III

Zone

0

1

2

20

21

22

Ex interface

X

X

X

X

X

X

Installation in

 

X

X

 

X*)

X*)

Class

I

II / III

Division

1

2

1

2

Ex interface

X

X

X

X

Installation in

X

X

X*)

X*)

*) suitable enclosure necessary

 
 
 
 

Digital Output Module 8-Channel Version Series 9475/.2-08-.. from Rev. F

 
Digital Output Module 8-Channel Version Series 9475/.2-08-.. from Rev. F
  • 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves
  • Intrinsically safe outputs Ex ia IIC
  • Additional input for "Outputs OFF" available (acc. to IEC 61508 up to SIL 2)
  • Galvanic isolation between outputs and system
  • Open-circuit and short-circuit monitoring for each field circuit
  • Functions with adjustable parameters
  • Module can be replaced in operation (hot swap)

 

Zone

0

1

2

20

21

22

Class

I

II / III

Zone

0

1

2

20

21

22

Ex interface

X

X

X

X

X

X

Installation in

 

X

X

 

X*)

X*)

Class

I

II / III

Division

1

2

1

2

Ex interface

X

X

X

X

Installation in

X

X

X*)

X*)

*) suitable enclosure necessary

 
 
 
 

Digital Output Module Relay and Sockets for Installation in Zone 1 / Div. 1 Series 9477/12; Series 9490

 
Digital Output Module Relay and Sockets for Installation in Zone 1 / Div. 1 Series 9477/12; Series 9490
  • 6 or 8 channels: volt-free relay contact, normally open
  • High switching capacity, up to 100 VA
  • Galvanic isolation between outputs and system
  • Connection of the field cables by means of Ex e terminals or conduit
  • Module can be replaced in operation (hot swap)

 

Zone

0

1

2

20

21

22

Class

I

II / III

Zone

0

1

2

20

21

22

Ex interface

 

X

X

     

Installation in

 

X

X

     

Class

I

II / III

Division

1

2

1

2

Ex interface

X

X

   

Installation in

X

X

   
 
 
 
 

Digital Output Module Relay Ex nA / NI Outputs, 8 Channels Series 9477/15

 
Digital Output Module Relay Ex nA / NI Outputs, 8 Channels Series 9477/15
  • 8 channels with output: volt-free relay contact, normally open
  • Outputs Ex nA and Non Incendive (non-sparking)
  • Galvanic isolation between outputs and system
  • Module can be replaced in operation (hot swap)

 

Zone

0

1

2

20

21

22

Class

I

II / III

Zone

0

1

2

20

21

22

Ex interface

   

X

   

X

Installation in

   

X

   

X*)

Class

I

II / III

Division

1

2

1

2

Ex interface

 

X

   

Installation in

 

X

   

*) suitable enclosure necessary

 
 
 
 

Digital Output Module Valve Series 9478

 
Digital Output Module Valve Series 9478
  • 8 integrated 3/2-port directional control valves for pneumatic valves
  • Additional Ex i input for "System OFF"
  • Monitoring of the electronic control of the 3/2-port directional control valves in regard to short circuit and wire breakage
  • Functions adjustable
  • Live module can be replaced (hot swap)
  ATEX / IECEx
Zone 0 1 2 20 21 22
Installation in   x x   x x

 

     
Tel: +234 807 991 3447  Fax:  +234 1 8237255   Email:  info@elemcong.com
Copy right Elemco International Limited. All rights reserved.